EoC devices:


Article NumberNameAcronym
383101EoC Controller 32/2CT32

383103

EoC Controller 64/4

CT64

383104

EoC Controller 32/2-B

CT32-B
383105EoC Controller 64/4-BCT64-B
383106EoC Controller 32/2-MCCT32-MC
383107EoC Controller 64/4-MCCT64-MC
383200EoC Coax WiFi EndpointEPC1W
383230EoC Ethernet WiFi EndpointEPE1W
383235EoC MediaConverter 1EMC1


TV-in:

  • TV-in RF connector on EoC Controller - combining the TV and G.hn signals on the EoC out ports
  • TV-in loops through 300MHz and above (200...300 MHz is filtered away by the controller)
  • TV-in attenuation is ~5dB for CT32 and ~10dB for CT64
  • TV-in attenuation is ~4dB for CT32-B and ~8dB for CT64-B


G.hn:

  • G.hn Wave 2 ITU-T G.9960 / ITU-T G.9963 (G.hn PHY) G.9962 (MAC & DLL)
  • G.hn operates in frequency range 2...200 MHz
  • G.hn output level is ~100dBµV (CT & EPC/EMC/MCC)
  • Max total G.hn throughput is 1.6 Gbps (DS/US as UDP traffic)
  • Low latency - down to ~1ms
  • Configurable G.hn notch filtering - allowing to omit or attenuate desired parts of the 2...200 MHz range
  • Configurable G.hn ports combining/bundling - supporting up to 64 Endpoints on the same coax cabling
  • Configurable G.hn Endpoint isolation - for network separation in MDU (appartments) installations
  • Dynamic G.hn bandwidth management with configurable bandwidth limitation per Endpoint


Network:

  • 10/100/1000 Gbps duplex enternet ports
  • Up to 128 VLANs (VIDs 1-4095), with access tagging, trunking and hybrid (EMC1 up to 16 trunk VLANs)
  • L2 Client Isolation - configurable per VLAN
  • QoS - VLAN CoS (PCP) and IP DSCP (ToS)
  • IGMPv1 and IGMPv2 - Snooping and multicast filtering
  • IGMP querier in EoC controller - participating in automatic election process
  • Private Network Zones - just-like-home local network experience in room/cabin (Endpoint as router with DHCP server)


Wi-Fi:

  • Dual band Wi-Fi (AC1200)
  • 2.4 GHz - 802.11 g/n, 2x2 MIMO, 20/40 MHz channel width, 300 Mbps
  • 5 GHz - 802.11 n/ac, 2x2 MU-MIMO, 20/40/80 MHz channel width, 867 Mbps
  • WPA/WPA2 Personal and Enterprise (RADIUS authentication)
  • Beamforming
  • Bandsteering (Between 2.4 GHz and 5 GHz on same Wi-Fi Endpoint)
  • Channel selection - Automatic or manual
  • Tx power - Automatic or manual
  • Up to 200 Wi-Fi clients per Endpoint
  • Up to 8 dual band SSIDs or 16 single band SSIDs per Wi-Fi Endpoint
  • Private SSIDs - just-like-home Wi-Fi experience, allowing in room/cabin Wi-Fi communication between connected devices, while still being isolated from clients connected to other Endpoints (VLAN client isolation must be enabled)


Management and Monitoring:

  • Web GUI
  • REST API
  • SNMPv2 and SNMPv3
  • SSH
  • RADIUS authentication for management access


Max Configuration Entities in EoC Controller:

  • VLANs: 128
  • SSIDs: 70
  • Private Network Zones: 70
  • Endpoints: 70
  • Endpoints configuration groups: 71
  • G.hn notch filters: 10
  • L2 Client Isolation trusted hosts (MAC whitelist): 7
  • NTP servers: 4
  • SSH keys: 4
  • Site GUI page EoC Controllers: 15


Login:

  • Connect the Laptop to the controller on Port 1 and open a browser
  • Type in ”setup.eoc/” or "192.168.10.1" in the Address Field & press <Enter>
  • Login in with the Admin account (‘admin’ / ‘admin’)


VLAN & Controller ports:

The default configuration for the ethernet port on the controller is:

  • Port 1: Configuration (DHCP server enabled)
  • Port 2: Default (VLAN 1)
  • Port 3: Default (VLAN 1)
  • Port 4: Default (VLAN 1)

Port 1-4 are changeable, from the web interface. Eth1 is not suitable for multicast.


Setup Wi-Fi:

  • SSID: TriaxSetup_XXXX
  • Key: SetupPasswordXXXX
  • XXXX = Last 4 digits of CTRL MAC


Group settings:


Group nameSSIDsEthernet rule

None

-

-

Setup

TriaxSetup_xxxx’

Setup (access)


Return path filter (383900):

  • TV 300...862MHz : 3dB
  • G.hn 2...200MHz: 1.5dB


Return path filter, narrow G.hn (383903):

  • TV 110...862MHz : 3dB
  • G.hn 2...85MHz: 1.5dB


Return path filter, Power pass (393910):

  • TV 300...862MHz : 3.5dB
  • G.hn 2...200MHz: 1.5dB
  • AC/DC pass (<65V/<1,5A)


HP Filter 258MHz F (383901):

  • 258...2400MHz : <1.2dB
  • 1...204MHz: >40dB