On the headend and modules, there are LED's indicating the status of the system. Alle these LED's combined, gives you a overview of the system state.
This we call 'System Monitoring'. This article will describe the meaning of the LED's, in 3 parts:
- System LED's
- Input Module LED's
- Output Module LED's
The article will not describe, how to fix any errors. Please see the related articles or contact support for further help.
System LED's
Four LED's are placed at the top of the output section of each headend unit, and provide information on the state of the headend and sub-units (if present).
The four LED's are named (from left to right):
The LEDs can be constant green / flashing green / constant red / off. The message being indicated are different for each LED.
The meaning of the LED's can be interpreted by the following schemes.
Headend type usage |
LED Name |
Color |
Message |
---|---|---|---|
Standalone |
System Status |
Constant Green |
Power is on and the headend is Operational. |
Flashing Green |
The headend is booting up. |
||
Red |
An error has been detected in the headend, which must be investigated. |
||
Tuner Status |
Constant Green |
The input module tuners are locked. |
|
Red |
One or more Input module tuners are not locked. |
||
Unit Link 1 |
Not used |
- |
|
Unit Link 2 |
Not used |
- |
Headend type Usage |
LED Name |
Colour |
Message |
---|---|---|---|
Main-Unit in multi-unit |
System Status |
Constant Green |
Power is on and the headend is Operational. |
Flashing Green |
The headend is booting up. |
||
Red |
An error has been detected in the headend, which must be investigated. |
||
Tuner Status |
Constant Green |
The input module tuners are locked. |
|
Red |
One or more Input module tuners are not locked. |
||
Unit Link 1 |
Constant Green |
Sub-unit 1 is connected to the main unit. |
|
Red |
There is a problem with the connection to the sub-unit 1. |
||
Off |
No sub-unit 1 is connected to the main unit. |
||
Unit Link 2 |
Constant Green |
Sub-unit 2 is connected to the main unit. |
|
Red |
There is a problem with the connection to the sub-unit 2. |
||
Off |
No sub-unit 2 is connected to the main unit. |
||
Sub-unit 1 in multi-unit |
System Status |
Constant Green |
Power is on and the headend is Operational. |
Flashing Green |
The headend is booting up. |
||
Red |
An error has been detected in the headend, which must be investigated. |
||
Tuner Status |
Constant Green |
The input module tuners are locked. |
|
Red |
One or more Input module tuners are not locked. |
||
Unit Link 1 |
Constant Green |
The sub-unit is connected to the main-unit. |
|
Red |
There is a problem with the connection to the main-unit. |
||
Off |
Sub-unit is not connected to main-unit. |
||
Unit Link 2 |
Constant Green |
The sub-unit is connected to sub-unit 2 |
|
Red |
There is a problem with the connection to sub-unit 2 |
||
Off |
Sub-unit is not connected to sub-unit 2 |
||
Sub-unit 2 in multi-unit |
System Status |
Constant Green |
Power is on and the headend is Operational. |
Flashing Green |
The headend is booting up. |
||
Red |
An error has been detected in the headend, which must be investigated. |
||
Tuner Status |
Constant Green |
The input module tuners are locked. |
|
Red |
One or more Input module tuners are not locked. |
||
Unit Link 1 |
Constant Green |
The sub-unit is connected to the main-unit. |
|
Red |
There is a problem with the connection to the main-unit. |
||
Off |
Sub-unit is not connected to main-unit. |
||
Unit Link 2 |
Constant Green |
The sub-unit is connected to sub-unit 1 |
|
Red |
There is a problem with the connection to sub-unit 1 |
||
Off |
Sub-unit is not connected to sub-unit 1 |
Input Modules LED's
There is a status LED on the front of each module. The LED indicates whether the module has locked on to a frequency or needs to be configured.
Color |
Message |
---|---|
Constant Green |
No errors and the module. |
Flashing Green |
The module has not been configured yet. |
Red |
The module has been configured. Error on the module (no lock / no service). |
Off |
Power has not been switched on. |
When you update the software of a module the status LED provides you with information about the updating process.
Color |
Message |
---|---|
Orange |
Boot loader state. |
Temporary off |
Initiation of the software update. |
Temporary green |
Every time the modules receives a valid data package. Repeated until the update is completed without errors. |
Red |
Software update failed. |
Output Modules LED's
There is a status LED on the front of each module. The LED indicates whether the module functions according to its purpose or fails.
Color |
Message |
---|---|
Constant Green |
The output module receives valid services. |
Flashing Green |
The output module receives data. |
Red |
When starting the TDX system the output module and the system controller negotiate connection speed. If the LED continues to be red either the output module or the system controller has not been inserted correctly. |
Off |
The output module has not been configured yet or the module has not been inserted correctly. |
When you update the software of a module the status LED provides you with information about the updating process.
Color |
Message |
---|---|
Orange |
Boot loader state. |
Temporary off |
Initiation of the software update. |
Temporary green |
Every time the modules receives a valid data package. Repeated until the update is completed without errors. |
Red |
Software update failed. |